品牌Hawke防爆格兰 | 有效期至长期有效 | 最后更新2024-11-05 20:30 |
浏览次数261 |
Hawke非铠接管式防爆格兰(SB474系列)
Hawke防爆格兰代理商:上海颐品自动化科技有限公司
关键词:Hawke防爆格兰,Hawke防爆葛兰,Hawke防爆填料函,Hawke防爆密封接头
Hawke非铠防爆格兰,Hawke铠装防爆格兰,Hawke防爆变径,Hawke防爆呼吸阀堵头
Hawke SB 474 Cable gland
Hawke非铠接管式防爆格兰(SB474系列)
Hawke代理商:上海颐品自动化科技有限公司
Hawke SB 474 cable glands are suitable for both outdoor and indoor use.
For particular use with:-
a) Cable inner sheaths that are not effectively filled, compact and/or circular, have tape bedding or have hygroscopic fillers.
b) Cables that exhibit ‘cold flow’ characteristics.
c) Enclosures for gas group IIC, under 2 litres in volume and containing an ignition source.
d) Enclosures for gas groups IIA or IIB, which are greater than 2 litres in volume and contain an ignition source
Hawke SB 474 cable glands are dual certified Exd and Exe and suitable for installation in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC.
When used in increased safety applications the Hawke cable gland can be used to terminate braided cables where the braid and the cable outer sheath enter into the electrical enclosure or junction box.
♦ Exdb IIC Gb, Exe IIC Gb, Extb IIIC, Db Non-aromoured Cables ATEX & IECEx Cable Gland.
Hawke SB 474 cable gland is suitable for cable termination and installation in Zone 1 (21), Zone 2 (22) and Division 2 hazardous areas.
-
Flameproof Exdb
-
Increased Safety Exeb
-
Dust Extb
-
Dual Certified Cable Gland For Hazardous Areas ATEX – IECEx
HAWKE SB 474 CABLE GLAND TECHNICAL SPECIFICATION
-
Hazardous Area Cable Gland Classification – Exdb IIC Gb, Exeb IIC Gb, Extb IIIC Db
-
Certificate No’s – baseefa06ATEX0056X and IECEx BAS 06.0013X
-
Cable Gland Zone Location – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC
-
Construction and Test Standards – IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31
-
Ingress Protection – IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X
-
Deluge Protection – DTS01
-
Operating Temperature Range -60°C to +80°C
CABLE GLAND SELECtION TABLE FOR HAWKE SB 474
Hawke Size Ref. | Male Entry Thread Size | Female Entry Thread Size | ‘G’ Compressed Length | Hexagon Dimensions | ||||
---|---|---|---|---|---|---|---|---|
Metric | NPT * | Metric | NPT # | Across Flats | Across Corners | |||
Standard | Option | |||||||
A | M20 | ¾” | ½” | M20 | – | 63.9 | 30.0 | 32.5 |
B | M25 | 1″ | ¾” | M25 | – | 52.8 | 30.0 | 39.5 |
C | M32 | 1¼” | 1″ | M32 | – | 69.5 | 46.0 | 50.5 |
All dimensions in millimetres (except * where dimensions are in inches).
Metric entry threads are 1.5mm pitch as standard.
# NPT female thread sizes equivalent to those shown in the table for the male thread size are available. Hexagon dimensions as shown may alter.
➡ Cembre cable lugs available to crimp and terminate cable conductors to ensure complete termination of cable.
CABLE GLAND MATERIAL & FINISH
Hawke SB 474 cable glands are manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard.
PREPARING CABLE & GLAND FOR INSTALLING HAWKE SB 474
CABLE PREPARATION
Pull sufficient length ‘I’ of cable through conduit/cable gland to suit equipment. Screw backnut (1) on to pre-threaded conduit/cable gland and tighten with spanner/wrench.
CABLE GLAND PREPARATION
Select the correct punch tool to suit conductor sizes (see table) and punch out the required number of holes in the seal using the indented positions as a guide. Pass the individual conductors through the appropriately sized punched holes in the seal (4) ensuring they are not twisted or kinked and slide down to backnut (1).
➡ Click Hawke Cable Glands to view the complete range of hazardous area glands certified according to ATEX & IECEx for Zone 1 / Zone 2.
Flameproof Exdb and Increased Safety Exeb (Dust Extb) Dual Certified glands from Hawke include – for further information review the product pages or contact us to discuss your cable gland requirements.
-
501/421 Cable Gland Unarmoured – outer cable sheath cable sealing
-
501/423 Cable Gland Unarmoured – flameproof seal to inner/outer cable sheath with IP seal on the outer sheath
-
501/453 Universal Cable Gland Wire Armoured Baided Steel Tape Armoured – indoor/outdoor hazardous areas
-
ICG 623 Barrier Gland Unarmoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas
-
ICG 653 Barrier Gland Armoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas
Hawke防爆格兰(Hawke Cable Gland)
Hazardous Area Cable Glands-ATEX IECEX,Exe,Exd Group II
Hawke防爆格兰代理商:上海颐品自动化科技有限公司
关键词:Hawke防爆格兰,Hawke防爆变径,Hawke防爆堵头,
Hawke防爆呼吸阀,Hawke防爆接线盒,Hawke防爆控制箱
Hawke防爆格兰等产品规格书及相关证书-请咨询上海颐品自动化科技有限公司